Series Z5 – Automatic transformer testing systems

A complete range for testing single-phase, three-phase and toroidal transformers, sized to power ratings, voltages and production volumes, from benchtop units to rotary tables.

Who it is for: manufacturers of power-supply and medium-power transformers.

Tests

Standard: electrical resistance, dielectric strength, measurement of electrical parameters.
Optional: earth bond, insulation, turns ratio, inductance, induced voltage test, secondary phasing, iron and copper losses, efficiency, Surge Test, Delta T measurement.

Models

Model Purpose
Z5/NCP (low power) Low-power single-phase and three-phase transformers, small and medium volumes, 1 or 2 alternating stations
Z5/NCP (medium power) Transformers from 30 to 200 kW (higher on request): copper and iron losses, efficiency, induced voltage, turns ratio
Z5/NCP-RT Rotary table for small transformers and large production runs, cycle of a few seconds, robot automation
B10/MRS Benchtop instrument for the turns ratio of large transformers, accuracy better than 0.1%

Measurement data

Test Values
Electrical resistance Kelvin 4-wire, 0.001 Ω–20 kΩ, 0.05 mΩ resolution, accuracy better than 0.5%
Dielectric strength 40–3,000 V AC (up to 50 kV on request), trip 0.5–30 mA
Insulation 40–2,800 V DC, 200 kΩ–1 GΩ
Earth bond 10 and 25 A AC
Induced voltage 4× rated frequency and 4× rated voltage, turn-to-turn short check

Configuration

8 to 32 terminations, 1–3 external workstations, 19″ touch Panel PC, data bank with filters, batch and serial number management, interface to line PLC.

Downloads

Included with every machine: one day of training at Aimotix, free TeamViewer remote support during the warranty period, calibration certificate, CE declaration, manual in Italian (other languages on request).

Request a Series Z5 demo

Quotations: sales@aimotix.com  ·  General information: info@aimotix.com
Landline +39 011 024 1424  |  Mobile +39 344 060 6405